FaceFocusVR

Safety

Everything you need to know about the safety of your FaceFocusVR kit.
Unsure about anything safety related? Join the Discord

Overview

Your Responsibility

No optical safety evaluation can account for all possible real-world use conditions. Infrared radiation is a natural component of environmental light exposure; however, excessive exposure to high-intensity optical sources may cause harm.

  • Never attempt to replace, disable, or modify safety-related components.
  • Discontinue use if visual discomfort occurs.

When to Stop

If you notice any unusual warmth or discomfort in your eyes, stop using the device. Minor warmth may be perceived depending on operating conditions. Discontinue use if you experience:

  • The eye-tracking camera image appears overexposed or washed out.
  • Dark spots in your vision or unusual visual disturbances.
  • Dry or strained eyes beyond what is normal for VR use.

Lab Tested

Exempt Group

EN 62471:2008

Independently tested by a third-party laboratory under EN 62471 (Photobiological Safety of Lamps and Lamp Systems) and classified in the Exempt Group, the lowest of the four risk groups the standard defines.

More information

The result

The FFVR-INDEX-V2 was classified in the Exempt Group for every hazard category evaluated, for both illuminated modules, at both distances it was tested at.

EN 62471 sorts optical sources into four photobiological risk groups, ordered from lowest to highest risk: Exempt, Risk Group 1 (Low Risk), Risk Group 2 (Moderate Risk) and Risk Group 3 (High Risk). Exempt is the lowest category the standard defines. A source lands there when it poses no photobiological hazard under any of the exposure conditions the standard evaluates, without needing a time limit or a warning label to stay safe.

However, a laboratory classification describes a device under defined test conditions. It is not a guarantee of safety under every possible real-world condition, and it is no substitute for sensible use. Always follow the safety notes at the top of this page.

What was tested, and how

  • Device: Eye & Face Tracking Kit for Valve Index, model FFVR-INDEX-V2
  • Components evaluated: the eye module and the face module. The left and right eye modules are identical in construction and driven by the same circuit, so the reports evaluate the single eye-module design.
  • Emitters: ROHM CSL1501RW1 in the eye module (860 nm peak) and XINGLIGHT XL-3216HIRC-850 in the face module (850 nm peak), both emitting continuously rather than in pulses
  • Standard: EN 62471:2008, Photobiological Safety of Lamps and Lamp Systems
  • Laboratory: Shenzhen Southern LCS Compliance Testing Co., Ltd.
  • Measurement system: EVERFINE OST-300 optical radiation safety test system
  • Operating conditions: DC 5 V supply, stable ambient of 25 ± 1 °C, and LED forward currents of 6.06 mA in the eye module and 9.1 mA in the face module

Why it was tested at two distances

EN 62471 reports hazard values at a fixed distance. For sources that are not general lighting service lamps, that distance is 200 mm. It is a reporting convention rather than a claim about how a product is used: fixing the distance is what allows results from different products to be compared on equal terms.

A headset does not sit 200 mm from the eye. The eye-module illuminators are roughly 15 mm away, well inside the standard’s reference distance, so a report at 200 mm alone would describe a configuration that never occurs in normal use. The hardware was therefore submitted twice:

  • At 200 mm, the standard’s reference distance. The configuration EN 62471 specifies, which makes the result directly comparable to any other product tested against the standard. Report LCSB03236073S, tested April 16, 2026.
  • At 15 mm, the actual operating distance. The distance at which the modules sit from the eye in normal use, recorded in the report as a customer-specified test distance. Report LCSB07106047S, tested July 24, 2026.

How close is too close?

The limit that governs an infrared source of this type is \(E_{IR}\), the infrared irradiance reaching the eye. EN 62471 caps it at \(100 \frac{\text{W}}{\text{m}^2}\) for exposures longer than 1000 s, the regime every VR session falls into. At the operating distance the reading is:

  • Eye module at 15 mm: \(0.19 \frac{\text{W}}{\text{m}^2}\), a factor of 530 below the limit

Having the same hardware measured at two distances makes it possible to extrapolate further inward. The emission turns out to fall off far more gently than a single point source would, because the illuminators are several separate emitters spread around the lens. Assuming the steeper inverse-square falloff regardless is therefore the conservative way to extrapolate, and that is what the figure below uses. It remains an extrapolation rather than a measurement: the reports state no measurement uncertainty, and LED binning and forward current vary between individual units.

Even on that pessimistic basis, the eye module would not reach the limit until roughly 0.65 mm from an emitter. That distance cannot occur in practice. The module housing holds the illuminators at their operating distance of about 15 mm and the eye cannot move inside it, so there is no position a wearer can reach where infrared exposure comes close to the limit.

The full reports